Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: M13

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $1000.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000-5000/set/month

Get Best Price
Highlight:

Front Flow CRAC unit HVAC

,

CRAC unit HVAC

,

Front Flow CRAC Unit

Cooling Capacity:
5-13KW
Color:
Black/Grey White/other Custom Colors
Mounting:
Floor Standing
Operating Voltage:
380/400 VAC,230 VAC,220V
Operation:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Air Flow:
Front Flow
Product:
Precision Air Conditioning Unit/ Data Center Cooling Unit /computer Room Unit /close Control Unit
Cooling Capacity:
5-13KW
Color:
Black/Grey White/other Custom Colors
Mounting:
Floor Standing
Operating Voltage:
380/400 VAC,230 VAC,220V
Operation:
Computer Room,Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Power:
3N-380V-50Hz,220v/50hz/60hz
Air Flow:
Front Flow
Product:
Precision Air Conditioning Unit/ Data Center Cooling Unit /computer Room Unit /close Control Unit
Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms

Coolsmart Computer Room Precision Air Conditioning ( 5kw-13kw) designed for small and medium-sized computer rooms

 

Product Introduction                              

Precision air conditioner special for the places where require strict temperature and humidity. The development trend is providing high capacity based on a small area. Midea provide safe, stable and energy efficient precision air conditioner products for users based on decades of years of air conditioning technology development.

 

 

 

 

Advantages                                                

High intelligent
• Adopting a new generation intelligent PLC microcomputer controller, large LCD screen, with background light, modular menu, English display
• Record data such as various status, alarms of the unit and historical data sharing
• Power-on data protection and power recovery automatic start-up design
• Powerful group control system of 32 sets units, energy efficiency management, timing rotation and fault braking switching, automatic implementation of group adaptive energy saving
 
High reliability
• 365 days, 24 hours continuous operation design
• High-quality parts from worId-famous brands that have been rigorously designed, manufactured, tested and certified.
• Advanced self-diagnosis and fault warning control system
• Unique self-balancing software to improve the
trouble-free running time and prolong the actual service life of key components of system
Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms 0

Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms 1

Technical Features                                      
Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms 2

High reliability

Provide Constant temperature & humidity, cleanness precision environment to ensure the main equipment in good running condition

24-hour running design guarantee main equipment operation safety

All units had passed a severe running test before delivery, which can ensure units’ high reliability.

 

High energy efficiency

SHR (sensible heat ratio) is larger than 90%.

Compressor EER is larger than 3.1

Optimal and high efficiency compressor and fan in CRAC industry.

Maximum evaporator in CRAC industry ensures the highest heat exchange efficiency.

Optimal CFD air duct design: minimum air duct resistance & minimumfan power

Inverter IDU: high efficiency & long working life

Advanced control logic: avoid competitive running and output cooling capacity according to actual cooling capacity demand.

 

Easy maintenance

Front panel maintenance: all maintenance operation can be finished

from the front panel

Air filter with metal frame: cleanable repeatedly with low maintenance cost.

Auto-clean function: lower maintenance work

Metal frame with marine protection grade: durable and less maintenance work.

All metal fans of ODU & IDU: durable & high end

Remote control: convenient management & maintenance

 

Multiple choice

Wide range of cooling capacity: 5.5kW~20.5kW

Multiple types:cooling only, cooling & electrical heating, constant temperature & humidity.

Multiple cooling modes:air cooled, Freon pump, water cooled & glycol cooled.

Multiple air supply modes:cap tuyere supply, air duct supply,

floorboard supply, etc.

Multiple refrigerant types:R22, R407C, R410A

Wide operation temperature range(ambient air temperature): standard type(-20℃~50℃), low temperature type(-40℃~50℃)

Customization:fit into your special requirements

Air Supply Method                                   

Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms 3

Technical Parameter                                
Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

 

Certificates                                               

Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms 4

 

Factory Details                                            

Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms 5

 

Delivery & Packing                                       

Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms 6

 

Case                                                

Front Flow CRAC Unit HVAC For Small And Medium Sized Computer Rooms 7