Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: XR060A
Payment & Shipping Terms
Minimum Order Quantity: 1Unit
Price: USD2000-30000/Unit
Packaging Details: Packed in plywooden case, standard export package
Delivery Time: 20-35Working Days
Payment Terms: T/T, L/C
Supply Ability: 1000/Month
Total Capacity: |
63.9 KW (24℃/50%RH) |
Compressor Refrigerant: |
R410A |
Air Flow: |
12500 M³/h |
Air Filter Level: |
≥G4 |
12500 M³/h: |
3Kg/h |
Reheat Capacity: |
6KW |
Weight: |
330 Kgs |
Dimension: |
600mm*1200mm*2000 Mm |
Total Capacity: |
63.9 KW (24℃/50%RH) |
Compressor Refrigerant: |
R410A |
Air Flow: |
12500 M³/h |
Air Filter Level: |
≥G4 |
12500 M³/h: |
3Kg/h |
Reheat Capacity: |
6KW |
Weight: |
330 Kgs |
Dimension: |
600mm*1200mm*2000 Mm |
DX CRA060A In-Row Series Precision Air Conditioner for Critical Application
Product Introduction The In-row air conditioner is a device placed between the columns of the server cabinet, and the heat source directly dissipates heat. The precision air conditioner in the inter-row room is a type of air conditioner in the room. It is a horizontal air supply unit. Due to the increasing heat dissipation of the server or communication equipment used in the data center, the traditional air conditioning refrigeration method can no longer meet the requirements of the equipment for temperature and humidity.
Feature & Benefits
|
Scope of Application
In row air conditioners are specially designed for modern modular data centers, such as high-thermal density data centers, various modular data centers, data centers with low PUE requirements, local hot spots in the equipment room, high-thermal density areas in medium-large equipment rooms, and data centers with limited equipment room area. |
Air Supply Method
Structure & Componenets
7 inch touch screen, running status and alarm display, advanced man-machine interface, to achieve simple and fast operation, professional, energy saving, intelligent and other functions.
Efficient DESIGN OF hydrophilic fin and inner threaded pipe, advanced technology, corrosion resistance, long life, high efficiency, and compressor and other refrigeration system components complete matching.
The backward EC fan has the advantages of high efficiency, energy saving, low noise, and continuous air volume.
Electrode humidifier, using tap water, with automatic cleaning function, quickly produce pure steam, maintenance without stopping. |
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |
Factory Details
Packing & Delivery
|
Cases
|