Home > products > Modular Data Centers > Floor Standing Modular Data Center Adaptation To Different Site Conditions

Floor Standing Modular Data Center Adaptation To Different Site Conditions

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: IDC

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 20-40 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

Double Row Modular Data Center

,

3Phase Modular Data Center

Cooling Capacity:
20-40KW
Condition:
Brand New
Mounting:
Floor Standing Units
Type:
Modular Data Centers
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Voltage:
380/400 VAC,230 VAC,220V
Refrigerant:
R22(R407C/R410A)
Application:
IDC/Large Data Companies/Government/Large Internet Enterprises
Cooling Capacity:
20-40KW
Condition:
Brand New
Mounting:
Floor Standing Units
Type:
Modular Data Centers
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Voltage:
380/400 VAC,230 VAC,220V
Refrigerant:
R22(R407C/R410A)
Application:
IDC/Large Data Companies/Government/Large Internet Enterprises
Floor Standing Modular Data Center Adaptation To Different Site Conditions

Modular Data Center For Data Center Solutions Adaptation To Different Site Conditions

 

 

Product Introduction                                                                       

                                 


Double row modular data center is a total solution for data center construction, highly integrated. A single pole block can package five major systems such as cabinets, cold aisle, power supply and distribution, all cold, management, etc. A module can fill all the basic conditions for stable operation of IT load. Micro module to double row cold channel mainly, but also can be made into a single row or hot channel form. Micro-module can support any cabinet position to adapt to different site conditions. The system adopts row-level near-end cooling method, which can provide improved return air temperature and further reduce PUE.

 

 

 

 

 

 

 

Benefits                                                                                           

Floor Standing Modular Data Center Adaptation To Different Site Conditions 0

                                       

Floor Standing Modular Data Center Adaptation To Different Site Conditions 1

Floor Standing Modular Data Center Adaptation To Different Site Conditions 2

 

Features                                                                                                                                                                          

Floor Standing Modular Data Center Adaptation To Different Site Conditions 3

Intelligent

Intelligent fire control can be implemented for every top plate. Once fire signal alarm in room, the top plate will open automatically,and fire extinguishing gases can enter the aisle.

 

Convinence

No threshold design,convinent for wheelbarrow.

 

Aesthetic

The window is made of prespective tempering glass with high mechanical strenth,good permeability.The Black coating of cold rolled steel plate borders and cabinet style is consistent and also coorinated with the computer room.

 

Automatical door structure

The sliding door can be closed automatically,can be installed door access system and can be opened from inside to outside if an emergency occurs.

 

Main Basic Unit Introduction                                                                                                                                   

Cooling System - In Row Air Conditioning Unit

Inverter In Row air conditioners are tailor-made high-density cabinets, adopts advanced frequency conversion technology and uses the environmentally friendly refrigerant R410A. The output cooling capacity is adjusted in real time according to the change of the detected load, to avoid frequent start and stop, and to ensure the temperature of the computer room environment.
Compared with fixed frequency air conditioners, the annual energy saving rate of variable frequency inter-train air conditioners can reach 29%
.

 

 

Floor Standing Modular Data Center Adaptation To Different Site Conditions 4

                                            

Technical Specification                                                                                           

                                            

Equipment System Item Parameter
System Dimension 1200mm enclosed cold/hot aisle dual-row cabinets
    1200mm enclosed cold/hot aisle Single-row cabinets
  Rack Quantity Dual Row Racks:≤48,Single Row Racks:≤24
Rack Dimensions 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
  Protection Class IP20
Enclosed Aisle Skylight 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
Power Supply and Distribution Dimension 600mm(W)*1200mm(D)*2000mm(H)
  UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
  Battery 40AH~240AH/12V Valve Regulated Lead Acid Battery
Cooling Indoor Unit Size 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
  Cooling Capacity Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
  Power Supply 3Phase 380VAC,50Hz
  Air Supply Front Supply
  Type Enclosed Hot/Cold Aisle
  Protection IP20
Monitoring System Monitoring Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm
  Equipment monitoring Power supply, battery, power distribution, air conditioning

 